Add readme
This commit is contained in:
@@ -3,7 +3,15 @@ Microsoft Visual Studio Solution File, Format Version 12.00
|
|||||||
# Visual Studio Version 17
|
# Visual Studio Version 17
|
||||||
VisualStudioVersion = 17.9.34728.123
|
VisualStudioVersion = 17.9.34728.123
|
||||||
MinimumVisualStudioVersion = 10.0.40219.1
|
MinimumVisualStudioVersion = 10.0.40219.1
|
||||||
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "Sharp7.Monitor", "Sharp7.Monitor\Sharp7.Monitor.csproj", "{9E5BF5E6-D1A1-4252-92DA-B66A04C744D0}"
|
Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "Sharp7.Monitor", "Sharp7.Monitor\Sharp7.Monitor.csproj", "{9E5BF5E6-D1A1-4252-92DA-B66A04C744D0}"
|
||||||
|
EndProject
|
||||||
|
Project("{2150E333-8FDC-42A3-9474-1A3956D46DE8}") = "_Solution Items", "_Solution Items", "{F66AD208-E4F7-453C-AC39-C0D6FF3D55F8}"
|
||||||
|
ProjectSection(SolutionItems) = preProject
|
||||||
|
.editorconfig = .editorconfig
|
||||||
|
.gitignore = .gitignore
|
||||||
|
publish.ps1 = publish.ps1
|
||||||
|
readme.md = readme.md
|
||||||
|
EndProjectSection
|
||||||
EndProject
|
EndProject
|
||||||
Global
|
Global
|
||||||
GlobalSection(SolutionConfigurationPlatforms) = preSolution
|
GlobalSection(SolutionConfigurationPlatforms) = preSolution
|
||||||
|
|||||||
BIN
docs/images/execute s7mon.gif
Normal file
BIN
docs/images/execute s7mon.gif
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 176 KiB |
80
readme.md
Normal file
80
readme.md
Normal file
@@ -0,0 +1,80 @@
|
|||||||
|
# Sharp7Monitor
|
||||||
|
|
||||||
|
Ever needed a simple console program to read some variables from a Siemens S7 PLC?
|
||||||
|
|
||||||
|
Sharp7Monitor is a .NET Console program written in C# that connects to a Siemens S7 PLC (Programmable Logic Controller) and reads specified variables.
|
||||||
|
It displays the variable values in a table format directly in your console. The content of these variables is automatically updated.
|
||||||
|
|
||||||
|
## Usage
|
||||||
|
|
||||||
|
1. **Installation**:
|
||||||
|
- Clone this repository or download the `s7mon.exe` binary.
|
||||||
|
- Ensure you have the necessary dependencies installed (e.g., .NET runtime).
|
||||||
|
|
||||||
|
2. **Invocation**:
|
||||||
|
- Open your terminal or command prompt.
|
||||||
|
- Navigate to the directory containing `s7mon.exe`.
|
||||||
|
- Run the following command:
|
||||||
|
```
|
||||||
|
.\s7mon.exe <IP_Address> <Variable1> <Variable2> ... <VariableN>
|
||||||
|
```
|
||||||
|
Replace `<IP_Address>` with the IP address of your Siemens S7 PLC, and list the desired variables (e.g., `DB2050.Byte1`, `DB2050.Int6`, etc.).
|
||||||
|
|
||||||
|
3. **Output**:
|
||||||
|
- The program will establish a connection to the PLC and continuously display the values of the specified variables in a table format.
|
||||||
|
- The table will automatically update as the variable values change.
|
||||||
|
- Press `Ctrl + C` to exit.
|
||||||
|
|
||||||
|
|
||||||
|
### Command
|
||||||
|
|
||||||
|
`s7mon.exe <IP address> [variables] [OPTIONS]`
|
||||||
|
|
||||||
|
### Arguments
|
||||||
|
|
||||||
|
<IP address> IP address of S7
|
||||||
|
[variables] Variables to read from S7, like Db200.Int4.
|
||||||
|
For format description see https://github.com/evopro-ag/Sharp7Reactive
|
||||||
|
|
||||||
|
### Options
|
||||||
|
```
|
||||||
|
DEFAULT
|
||||||
|
-h, --help Prints help information
|
||||||
|
-c, --cpu 0 CPU MPI address of S7 instance.
|
||||||
|
See https://github.com/fbarresi/Sharp7/wiki/Connection#rack-and-slot.
|
||||||
|
|
||||||
|
-r, --rack 0 Rack number of S7 instance.
|
||||||
|
See https://github.com/fbarresi/Sharp7/wiki/Connection#rack-and-slot.
|
||||||
|
```
|
||||||
|
|
||||||
|
|
||||||
|
### Example Invocation
|
||||||
|
|
||||||
|
```powershell
|
||||||
|
.\s7mon.exe 10.30.110.62 DB2050.Byte1 DB2050.Byte2.4 DB2050.Int6 DB2050.Real34 DB2050.String50.20
|
||||||
|
```
|
||||||
|
|
||||||
|
### Configure Cpu and Rack
|
||||||
|
|
||||||
|
Use `--cpu` and `--rack` parameters to specity the S7 instance to connect to. The required values depend on
|
||||||
|
the S7 you are using and it's configuration. You can find more information in the
|
||||||
|
[Sharp 7 docs](https://github.com/fbarresi/Sharp7/wiki/Connection#rack-and-slot).
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
## Contributing
|
||||||
|
|
||||||
|
Contributions are welcome! If you encounter any issues or have suggestions for improvements, feel free to open an issue or submit a pull request.
|
||||||
|
|
||||||
|
## License
|
||||||
|
|
||||||
|
This project is licensed under the MIT License - see the LICENSE file for details.
|
||||||
|
|
||||||
|
## On the shoulders of giants
|
||||||
|
|
||||||
|
This project is based on great libraries:
|
||||||
|
|
||||||
|
- The [Sharp 7](https://github.com/fbarresi/Sharp7) S7 PLC driver, based on [Snap 7](https://snap7.sourceforge.net/) by Davide Nardella
|
||||||
|
- [Sharp 7 Reactive](https://github.com/evopro-ag/Sharp7Reactive)
|
||||||
|
- [Spectre.Console](https://github.com/spectreconsole/spectre.console)
|
||||||
|
|
||||||