mirror of
https://github.com/evopro-ag/Sharp7Reactive.git
synced 2025-12-16 19:52:53 +00:00
Set s7Connector in constructor
This commit is contained in:
@@ -13,14 +13,14 @@ namespace Sharp7.Rx;
|
|||||||
|
|
||||||
internal class Sharp7Connector : IS7Connector
|
internal class Sharp7Connector : IS7Connector
|
||||||
{
|
{
|
||||||
private readonly BehaviorSubject<ConnectionState> connectionStateSubject = new BehaviorSubject<ConnectionState>(Enums.ConnectionState.Initial);
|
private readonly BehaviorSubject<ConnectionState> connectionStateSubject = new(Enums.ConnectionState.Initial);
|
||||||
private readonly int cpuSlotNr;
|
private readonly int cpuSlotNr;
|
||||||
|
|
||||||
private readonly CompositeDisposable disposables = new CompositeDisposable();
|
private readonly CompositeDisposable disposables = new();
|
||||||
private readonly string ipAddress;
|
private readonly string ipAddress;
|
||||||
private readonly int port;
|
private readonly int port;
|
||||||
private readonly int rackNr;
|
private readonly int rackNr;
|
||||||
private readonly LimitedConcurrencyLevelTaskScheduler scheduler = new LimitedConcurrencyLevelTaskScheduler(maxDegreeOfParallelism: 1);
|
private readonly LimitedConcurrencyLevelTaskScheduler scheduler = new(maxDegreeOfParallelism: 1);
|
||||||
private readonly IS7VariableNameParser variableNameParser;
|
private readonly IS7VariableNameParser variableNameParser;
|
||||||
private bool disposed;
|
private bool disposed;
|
||||||
|
|
||||||
|
|||||||
@@ -14,13 +14,13 @@ namespace Sharp7.Rx;
|
|||||||
|
|
||||||
public class Sharp7Plc : IPlc
|
public class Sharp7Plc : IPlc
|
||||||
{
|
{
|
||||||
protected readonly CompositeDisposable Disposables = new CompositeDisposable();
|
private readonly CompositeDisposable disposables = new();
|
||||||
private readonly ConcurrentSubjectDictionary<string, byte[]> multiVariableSubscriptions = new ConcurrentSubjectDictionary<string, byte[]>(StringComparer.InvariantCultureIgnoreCase);
|
private readonly ConcurrentSubjectDictionary<string, byte[]> multiVariableSubscriptions = new(StringComparer.InvariantCultureIgnoreCase);
|
||||||
private readonly List<long> performanceCoutner = new List<long>(1000);
|
private readonly List<long> performanceCoutner = new(1000);
|
||||||
private readonly PlcConnectionSettings plcConnectionSettings;
|
private readonly PlcConnectionSettings plcConnectionSettings;
|
||||||
private readonly IS7VariableNameParser varaibleNameParser = new CacheVariableNameParser(new S7VariableNameParser());
|
private readonly IS7VariableNameParser varaibleNameParser = new CacheVariableNameParser(new S7VariableNameParser());
|
||||||
private bool disposed;
|
private bool disposed;
|
||||||
private IS7Connector s7Connector;
|
private Sharp7Connector s7Connector;
|
||||||
|
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -44,13 +44,26 @@ public class Sharp7Plc : IPlc
|
|||||||
public Sharp7Plc(string ipAddress, int rackNumber, int cpuMpiAddress, int port = 102, TimeSpan? multiVarRequestCycleTime = null)
|
public Sharp7Plc(string ipAddress, int rackNumber, int cpuMpiAddress, int port = 102, TimeSpan? multiVarRequestCycleTime = null)
|
||||||
{
|
{
|
||||||
plcConnectionSettings = new PlcConnectionSettings {IpAddress = ipAddress, RackNumber = rackNumber, CpuMpiAddress = cpuMpiAddress, Port = port};
|
plcConnectionSettings = new PlcConnectionSettings {IpAddress = ipAddress, RackNumber = rackNumber, CpuMpiAddress = cpuMpiAddress, Port = port};
|
||||||
|
s7Connector = new Sharp7Connector(plcConnectionSettings, varaibleNameParser);
|
||||||
|
ConnectionState = s7Connector.ConnectionState;
|
||||||
|
|
||||||
if (multiVarRequestCycleTime != null && multiVarRequestCycleTime > TimeSpan.FromMilliseconds(5))
|
if (multiVarRequestCycleTime != null)
|
||||||
|
{
|
||||||
|
if (multiVarRequestCycleTime < TimeSpan.FromMilliseconds(5))
|
||||||
|
MultiVarRequestCycleTime = TimeSpan.FromMilliseconds(5);
|
||||||
|
else
|
||||||
MultiVarRequestCycleTime = multiVarRequestCycleTime.Value;
|
MultiVarRequestCycleTime = multiVarRequestCycleTime.Value;
|
||||||
}
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
public IObservable<ConnectionState> ConnectionState { get; }
|
||||||
|
|
||||||
|
public ILogger Logger
|
||||||
|
{
|
||||||
|
get => s7Connector.Logger;
|
||||||
|
set => s7Connector.Logger = value;
|
||||||
|
}
|
||||||
|
|
||||||
public IObservable<ConnectionState> ConnectionState { get; private set; }
|
|
||||||
public ILogger Logger { get; set; }
|
|
||||||
public TimeSpan MultiVarRequestCycleTime { get; } = TimeSpan.FromSeconds(0.1);
|
public TimeSpan MultiVarRequestCycleTime { get; } = TimeSpan.FromSeconds(0.1);
|
||||||
|
|
||||||
public int MultiVarRequestMaxItems { get; set; } = 16;
|
public int MultiVarRequestMaxItems { get; set; } = 16;
|
||||||
@@ -108,9 +121,6 @@ public class Sharp7Plc : IPlc
|
|||||||
|
|
||||||
public async Task<bool> InitializeAsync()
|
public async Task<bool> InitializeAsync()
|
||||||
{
|
{
|
||||||
s7Connector = new Sharp7Connector(plcConnectionSettings, varaibleNameParser) {Logger = Logger};
|
|
||||||
ConnectionState = s7Connector.ConnectionState;
|
|
||||||
|
|
||||||
await s7Connector.InitializeAsync();
|
await s7Connector.InitializeAsync();
|
||||||
|
|
||||||
#pragma warning disable 4014
|
#pragma warning disable 4014
|
||||||
@@ -128,7 +138,7 @@ public class Sharp7Plc : IPlc
|
|||||||
#pragma warning restore 4014
|
#pragma warning restore 4014
|
||||||
|
|
||||||
RunNotifications(s7Connector, MultiVarRequestCycleTime)
|
RunNotifications(s7Connector, MultiVarRequestCycleTime)
|
||||||
.AddDisposableTo(Disposables);
|
.AddDisposableTo(disposables);
|
||||||
|
|
||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
@@ -207,7 +217,7 @@ public class Sharp7Plc : IPlc
|
|||||||
|
|
||||||
if (disposing)
|
if (disposing)
|
||||||
{
|
{
|
||||||
Disposables.Dispose();
|
disposables.Dispose();
|
||||||
|
|
||||||
if (s7Connector != null)
|
if (s7Connector != null)
|
||||||
{
|
{
|
||||||
@@ -254,7 +264,8 @@ public class Sharp7Plc : IPlc
|
|||||||
var min = performanceCoutner.Min();
|
var min = performanceCoutner.Min();
|
||||||
var max = performanceCoutner.Max();
|
var max = performanceCoutner.Max();
|
||||||
|
|
||||||
Logger?.LogTrace("Performance statistic during {0} elements of plc notification. Min: {1}, Max: {2}, Average: {3}, Plc: '{4}', Number of variables: {5}, Batch size: {6}", performanceCoutner.Capacity, min, max, average, plcConnectionSettings.IpAddress,
|
Logger?.LogTrace("Performance statistic during {0} elements of plc notification. Min: {1}, Max: {2}, Average: {3}, Plc: '{4}', Number of variables: {5}, Batch size: {6}",
|
||||||
|
performanceCoutner.Capacity, min, max, average, plcConnectionSettings.IpAddress,
|
||||||
multiVariableSubscriptions.ExistingKeys.Count(),
|
multiVariableSubscriptions.ExistingKeys.Count(),
|
||||||
MultiVarRequestMaxItems);
|
MultiVarRequestMaxItems);
|
||||||
performanceCoutner.Clear();
|
performanceCoutner.Clear();
|
||||||
|
|||||||
Reference in New Issue