using System.Diagnostics;
|
|
using System.Reactive;
|
|
using System.Reactive.Disposables;
|
|
using System.Reactive.Linq;
|
|
using Microsoft.Extensions.Logging;
|
|
using Sharp7.Rx.Basics;
|
|
using Sharp7.Rx.Enums;
|
|
using Sharp7.Rx.Extensions;
|
|
using Sharp7.Rx.Interfaces;
|
|
using Sharp7.Rx.Settings;
|
|
|
|
namespace Sharp7.Rx;
|
|
|
|
public class Sharp7Plc : IPlc
|
|
{
|
|
private readonly CompositeDisposable disposables = new();
|
|
private readonly ConcurrentSubjectDictionary<string, byte[]> multiVariableSubscriptions = new(StringComparer.InvariantCultureIgnoreCase);
|
|
private readonly List<long> performanceCoutner = new(1000);
|
|
private readonly PlcConnectionSettings plcConnectionSettings;
|
|
private readonly IS7VariableNameParser varaibleNameParser = new CacheVariableNameParser(new S7VariableNameParser());
|
|
private bool disposed;
|
|
private Sharp7Connector s7Connector;
|
|
|
|
|
|
/// <summary>
|
|
/// </summary>
|
|
/// <param name="ipAddress"></param>
|
|
/// <param name="rackNumber"></param>
|
|
/// <param name="cpuMpiAddress"></param>
|
|
/// <param name="port"></param>
|
|
/// <param name="multiVarRequestCycleTime">
|
|
/// <para>
|
|
/// Polling interval used to read multi variable requests from PLC.
|
|
/// </para>
|
|
/// <para>
|
|
/// This is the wait time between two successive reads from PLC and determines the
|
|
/// time resolution for all variable reads reated with CreateNotification.
|
|
/// </para>
|
|
/// <para>
|
|
/// Default is 100 ms. The minimum supported time is 5 ms.
|
|
/// </para>
|
|
/// </param>
|
|
public Sharp7Plc(string ipAddress, int rackNumber, int cpuMpiAddress, int port = 102, TimeSpan? multiVarRequestCycleTime = null)
|
|
{
|
|
plcConnectionSettings = new PlcConnectionSettings {IpAddress = ipAddress, RackNumber = rackNumber, CpuMpiAddress = cpuMpiAddress, Port = port};
|
|
s7Connector = new Sharp7Connector(plcConnectionSettings, varaibleNameParser);
|
|
ConnectionState = s7Connector.ConnectionState;
|
|
|
|
if (multiVarRequestCycleTime != null)
|
|
{
|
|
if (multiVarRequestCycleTime < TimeSpan.FromMilliseconds(5))
|
|
MultiVarRequestCycleTime = TimeSpan.FromMilliseconds(5);
|
|
else
|
|
MultiVarRequestCycleTime = multiVarRequestCycleTime.Value;
|
|
}
|
|
}
|
|
|
|
public IObservable<ConnectionState> ConnectionState { get; }
|
|
|
|
public ILogger Logger
|
|
{
|
|
get => s7Connector.Logger;
|
|
set => s7Connector.Logger = value;
|
|
}
|
|
|
|
public TimeSpan MultiVarRequestCycleTime { get; } = TimeSpan.FromSeconds(0.1);
|
|
|
|
public int MultiVarRequestMaxItems { get; set; } = 16;
|
|
|
|
public void Dispose()
|
|
{
|
|
Dispose(true);
|
|
GC.SuppressFinalize(this);
|
|
}
|
|
|
|
public IObservable<TValue> CreateNotification<TValue>(string variableName, TransmissionMode transmissionMode)
|
|
{
|
|
return Observable.Create<TValue>(observer =>
|
|
{
|
|
var address = varaibleNameParser.Parse(variableName);
|
|
if (address == null) throw new ArgumentException("Input variable name is not valid", nameof(variableName));
|
|
|
|
var disp = new CompositeDisposable();
|
|
var disposeableContainer = multiVariableSubscriptions.GetOrCreateObservable(variableName);
|
|
disposeableContainer.AddDisposableTo(disp);
|
|
|
|
var observable =
|
|
// Directly read variable first.
|
|
// This will propagate any errors due to reading from invalid addresses.
|
|
Observable.FromAsync(() => GetValue<TValue>(variableName))
|
|
.Concat(
|
|
disposeableContainer.Observable
|
|
.Select(bytes => S7ValueConverter.ReadFromBuffer<TValue>(bytes, address))
|
|
);
|
|
|
|
if (transmissionMode == TransmissionMode.OnChange)
|
|
observable = observable.DistinctUntilChanged();
|
|
|
|
observable.Subscribe(observer)
|
|
.AddDisposableTo(disp);
|
|
|
|
return disp;
|
|
});
|
|
}
|
|
|
|
public Task<TValue> GetValue<TValue>(string variableName)
|
|
{
|
|
return GetValue<TValue>(variableName, CancellationToken.None);
|
|
}
|
|
|
|
|
|
public Task SetValue<TValue>(string variableName, TValue value)
|
|
{
|
|
return SetValue(variableName, value, CancellationToken.None);
|
|
}
|
|
|
|
|
|
public async Task<TValue> GetValue<TValue>(string variableName, CancellationToken token)
|
|
{
|
|
var address = varaibleNameParser.Parse(variableName);
|
|
if (address == null) throw new ArgumentException("Input variable name is not valid", nameof(variableName));
|
|
|
|
var data = await s7Connector.ReadBytes(address.Operand, address.Start, address.Length, address.DbNr, token);
|
|
return S7ValueConverter.ReadFromBuffer<TValue>(data, address);
|
|
}
|
|
|
|
public async Task<bool> InitializeAsync()
|
|
{
|
|
await s7Connector.InitializeAsync();
|
|
|
|
#pragma warning disable 4014
|
|
Task.Run(async () =>
|
|
{
|
|
try
|
|
{
|
|
await s7Connector.Connect();
|
|
}
|
|
catch (Exception e)
|
|
{
|
|
Logger?.LogError(e, "Error while connecting to PLC");
|
|
}
|
|
});
|
|
#pragma warning restore 4014
|
|
|
|
RunNotifications(s7Connector, MultiVarRequestCycleTime)
|
|
.AddDisposableTo(disposables);
|
|
|
|
return true;
|
|
}
|
|
|
|
public async Task SetValue<TValue>(string variableName, TValue value, CancellationToken token)
|
|
{
|
|
var address = varaibleNameParser.Parse(variableName);
|
|
if (address == null) throw new ArgumentException("Input variable name is not valid", "variableName");
|
|
|
|
if (typeof(TValue) == typeof(bool))
|
|
{
|
|
// Special handling for bools, which are written on a by-bit basis. Writing a complete byte would
|
|
// overwrite other bits within this byte.
|
|
|
|
if (address.Bit == null)
|
|
throw new InvalidOperationException("Address must have a Bit to write a bool.");
|
|
|
|
await s7Connector.WriteBit(address.Operand, address.Start, address.Bit.Value, (bool) (object) value, address.DbNr, token);
|
|
}
|
|
else
|
|
{
|
|
// TODO: Use ArrayPool.Rent() once we drop Framwework support
|
|
var bytes = new byte[address.BufferLength];
|
|
S7ValueConverter.WriteToBuffer(bytes, value, address);
|
|
|
|
await s7Connector.WriteBytes(address.Operand, address.Start, bytes, address.DbNr, token);
|
|
}
|
|
}
|
|
|
|
protected virtual void Dispose(bool disposing)
|
|
{
|
|
if (disposed) return;
|
|
disposed = true;
|
|
|
|
if (disposing)
|
|
{
|
|
disposables.Dispose();
|
|
|
|
if (s7Connector != null)
|
|
{
|
|
s7Connector.Disconnect().Wait();
|
|
s7Connector.Dispose();
|
|
s7Connector = null;
|
|
}
|
|
|
|
multiVariableSubscriptions.Dispose();
|
|
}
|
|
}
|
|
|
|
private async Task<Unit> GetAllValues(bool connected, IS7Connector connector)
|
|
{
|
|
if (!connected)
|
|
return Unit.Default;
|
|
|
|
if (multiVariableSubscriptions.ExistingKeys.IsEmpty())
|
|
return Unit.Default;
|
|
|
|
var stopWatch = Stopwatch.StartNew();
|
|
foreach (var partsOfMultiVarRequest in multiVariableSubscriptions.ExistingKeys.Buffer(MultiVarRequestMaxItems))
|
|
{
|
|
var multiVarRequest = await connector.ExecuteMultiVarRequest(partsOfMultiVarRequest as IReadOnlyList<string>);
|
|
|
|
foreach (var pair in multiVarRequest)
|
|
if (multiVariableSubscriptions.TryGetObserver(pair.Key, out var subject))
|
|
subject.OnNext(pair.Value);
|
|
}
|
|
|
|
stopWatch.Stop();
|
|
performanceCoutner.Add(stopWatch.ElapsedMilliseconds);
|
|
|
|
PrintAndResetPerformanceStatistik();
|
|
|
|
return Unit.Default;
|
|
}
|
|
|
|
private void PrintAndResetPerformanceStatistik()
|
|
{
|
|
if (performanceCoutner.Count == performanceCoutner.Capacity)
|
|
{
|
|
var average = performanceCoutner.Average();
|
|
var min = performanceCoutner.Min();
|
|
var max = performanceCoutner.Max();
|
|
|
|
Logger?.LogTrace("Performance statistic during {0} elements of plc notification. Min: {1}, Max: {2}, Average: {3}, Plc: '{4}', Number of variables: {5}, Batch size: {6}",
|
|
performanceCoutner.Capacity, min, max, average, plcConnectionSettings.IpAddress,
|
|
multiVariableSubscriptions.ExistingKeys.Count(),
|
|
MultiVarRequestMaxItems);
|
|
performanceCoutner.Clear();
|
|
}
|
|
}
|
|
|
|
private IDisposable RunNotifications(IS7Connector connector, TimeSpan cycle)
|
|
{
|
|
return ConnectionState.FirstAsync()
|
|
.Select(states => states == Enums.ConnectionState.Connected)
|
|
.SelectMany(connected => GetAllValues(connected, connector))
|
|
.RepeatAfterDelay(MultiVarRequestCycleTime)
|
|
.LogAndRetryAfterDelay(Logger, cycle, "Error while getting batch notifications from plc")
|
|
.Subscribe();
|
|
}
|
|
|
|
~Sharp7Plc()
|
|
{
|
|
Dispose(false);
|
|
}
|
|
}
|